{"id":2255,"date":"2014-03-11T14:02:27","date_gmt":"2014-03-11T12:02:27","guid":{"rendered":"http:\/\/fkh.ch\/en\/dienstleistungen\/pruefung-von-hs-betriebsmitteln-vor-ort\/transformatoren-und-andere-apparate\/"},"modified":"2019-11-28T13:25:24","modified_gmt":"2019-11-28T12:25:24","slug":"transformatoren-und-andere-apparate","status":"publish","type":"page","link":"https:\/\/fkh.ch\/en\/dienstleistungen\/pruefung-von-hs-betriebsmitteln-vor-ort\/transformatoren-und-andere-apparate\/","title":{"rendered":"Power transformer diagnostics"},"content":{"rendered":"<div id=\"attachment_1380\" style=\"width: 310px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/fkh.ch\/wp-content\/uploads\/2014\/03\/TE-Pr\u00fcfung-Erregung-Dieselgenerator-300x196.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1380\" class=\"wp-image-3107 size-medium\" src=\"https:\/\/fkh.ch\/wp-content\/uploads\/2014\/03\/TE-Pr\u00fcfung-Erregung-Dieselgenerator-300x196.jpg\" alt=\" Discharge measurement\" width=\"300\" height=\"196\" srcset=\"https:\/\/fkh.ch\/wp-content\/uploads\/2014\/03\/TE-Pr\u00fcfung-Erregung-Dieselgenerator-300x196.jpg 300w, https:\/\/fkh.ch\/wp-content\/uploads\/2014\/03\/TE-Pr\u00fcfung-Erregung-Dieselgenerator-768x501.jpg 768w, https:\/\/fkh.ch\/wp-content\/uploads\/2014\/03\/TE-Pr\u00fcfung-Erregung-Dieselgenerator-1024x667.jpg 1024w, https:\/\/fkh.ch\/wp-content\/uploads\/2014\/03\/TE-Pr\u00fcfung-Erregung-Dieselgenerator-230x150.jpg 230w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-1380\" class=\"wp-caption-text\">Discharge measurement<\/p><\/div>\n<p>FKH offers on-site diagnostic measurements for both new and service-aged power transformers. For measurements in connection with commissioning, the focus is on inspection of assembly, installation and oil impregnation, and also on characterisation of the transformer for subsequent comparisons (fingerprint in new condition). Diagnostic measurements on service-aged transformers are used to determine the condition of the insulation and to arrive at decisions regarding continued operation, the need for maintenance measures and planning of future inspections.<\/p>\n<p>FKH has offered diagnostic measurements on transformers since the 1990s. During this period, important basic knowledge was built up under the auspices of a project undertaken jointly with Switzerland&#8217;s technical colleges and universities, sponsored by the Project and Study Foundation of the Swiss Electricity Companies (PSEL).<\/p>\n<p>&nbsp;<\/p>\n<h2 style=\"text-align: justify;\">\u00a0<strong>Test methods offered<\/strong><\/h2>\n<p>&nbsp;<\/p>\n<div id=\"attachment_1463\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/fkh.ch\/wp-content\/uploads\/2014\/07\/Trafo-Diagramm4-300x204.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1463\" class=\"wp-image-3145 size-medium\" src=\"https:\/\/fkh.ch\/wp-content\/uploads\/2014\/07\/Trafo-Diagramm4-300x204.png\" alt=\"Partial discharge graph, measured on a transformer\" width=\"300\" height=\"204\" srcset=\"https:\/\/fkh.ch\/wp-content\/uploads\/2014\/07\/Trafo-Diagramm4-300x204.png 300w, https:\/\/fkh.ch\/wp-content\/uploads\/2014\/07\/Trafo-Diagramm4.png 735w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-1463\" class=\"wp-caption-text\">Partial discharge graph, measured on a transformer<\/p><\/div>\n<h3 style=\"text-align: justify;\">High-voltage partial discharge tests with electrical and acoustic detection during external voltage application or induced voltage testing<\/h3>\n<p style=\"text-align: justify;\">Offline partial discharge measurement is the most meaningful test for the detection of local weak points in the insulation and is used to identify faults.<\/p>\n<h3 style=\"text-align: justify;\">Short-circuit and open-circuit impedance measurements<\/h3>\n<p style=\"text-align: justify;\">These measurements allow direct comparisons with the factory acceptance measurements so that major faults on the windings and the core are identified.<\/p>\n<h3 style=\"text-align: justify;\">Frequency response analysis (FRA)<\/h3>\n<div id=\"attachment_1490\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/fkh.ch\/wp-content\/uploads\/2014\/03\/Trafo7-300x184.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1490\" class=\"wp-image-3165 size-medium\" src=\"https:\/\/fkh.ch\/wp-content\/uploads\/2014\/03\/Trafo7-300x184.png\" alt=\"FRA measurements on a 3-phase transformer\" width=\"300\" height=\"184\" srcset=\"https:\/\/fkh.ch\/wp-content\/uploads\/2014\/03\/Trafo7-300x184.png 300w, https:\/\/fkh.ch\/wp-content\/uploads\/2014\/03\/Trafo7-768x471.png 768w, https:\/\/fkh.ch\/wp-content\/uploads\/2014\/03\/Trafo7-1024x628.png 1024w, https:\/\/fkh.ch\/wp-content\/uploads\/2014\/03\/Trafo7.png 1215w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-1490\" class=\"wp-caption-text\">FRA measurements on a 3-phase transformer<\/p><\/div>\n<p style=\"text-align: justify;\">Frequency response analysis or FRA is a comparative method that indicates geometric changes to windings, caused (for example) by short-circuit forces or shocks and vibrations during transportation.<\/p>\n<h3 style=\"text-align: justify;\">Ratio measurement<\/h3>\n<p style=\"text-align: justify;\">This measurement is used to detect any coil short-circuits or faults on the onload tap changer.<\/p>\n<h3 style=\"text-align: justify;\"><\/h3>\n<h3 style=\"text-align: justify;\">PDC measurement; analysis of polarisation and depolarisation currents<\/h3>\n<div id=\"attachment_1465\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/fkh.ch\/wp-content\/uploads\/2014\/07\/Trafo-Diagramm6-300x228.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1465\" class=\"wp-image-3149 size-medium\" src=\"https:\/\/fkh.ch\/wp-content\/uploads\/2014\/07\/Trafo-Diagramm6-300x228.png\" alt=\"Presentation and evaluation of the PDC measurement\" width=\"300\" height=\"228\" srcset=\"https:\/\/fkh.ch\/wp-content\/uploads\/2014\/07\/Trafo-Diagramm6-300x228.png 300w, https:\/\/fkh.ch\/wp-content\/uploads\/2014\/07\/Trafo-Diagramm6-768x582.png 768w, https:\/\/fkh.ch\/wp-content\/uploads\/2014\/07\/Trafo-Diagramm6-1024x777.png 1024w, https:\/\/fkh.ch\/wp-content\/uploads\/2014\/07\/Trafo-Diagramm6.png 1920w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-1465\" class=\"wp-caption-text\">Presentation and evaluation of the PDC measurement<\/p><\/div>\n<p style=\"text-align: justify;\">This method is used to determine the proportion of polarisable substances in the insulation. This makes it possible to estimate the water content in the pressboard.<\/p>\n<h3 style=\"text-align: justify;\">DC (Direct Current)- resistance measurement<\/h3>\n<p style=\"text-align: justify;\">This measurement identifies changes of resitance and coil short-circuits. Contact resistances can also be determined. Recording the switching operations performed by onload tap changers (dynamic measurement) makes it possible to assess whether the contacts are switching correctly.<\/p>\n<h3 style=\"text-align: justify;\"><\/h3>\n<h3 style=\"text-align: justify;\">C-tan(\u03b4) measurement of bushings<\/h3>\n<p style=\"text-align: justify;\">This measurement is used to determine the ageing condition of the bushing insulation.<\/p>\n<h3 style=\"text-align: justify;\"><a href=\"https:\/\/fkh.ch\/wp-content\/uploads\/2019\/02\/Trafo_2-300x205.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4418 size-medium\" src=\"https:\/\/fkh.ch\/wp-content\/uploads\/2019\/02\/Trafo_2-300x205.png\" alt=\"\" width=\"300\" height=\"205\" srcset=\"https:\/\/fkh.ch\/wp-content\/uploads\/2019\/02\/Trafo_2-300x205.png 300w, https:\/\/fkh.ch\/wp-content\/uploads\/2019\/02\/Trafo_2-768x524.png 768w, https:\/\/fkh.ch\/wp-content\/uploads\/2019\/02\/Trafo_2-1024x699.png 1024w, https:\/\/fkh.ch\/wp-content\/uploads\/2019\/02\/Trafo_2.png 1473w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a>Recording of inrush current<\/h3>\n<p style=\"text-align: justify;\">Measurements of switch-on current provide information about the interaction between the transformer core, the grid and the protective devices, and also about the mechanical stress on the windings when the transformer is switched on.<\/p>\n<h3 style=\"text-align: justify;\">Oil analyses (e.g. dielectric-chemical oil analysis, gas-in-oil analysis, furan analysis)<\/h3>\n<p>Procedures to analyse oil deliver specific information about many aspects of the condition of the insulation: general condition of the oil, fault detection based on the composition of the dissolved\u00a0 gases, indications of cellulose decomposition and other ageing processes (For more details, see <a href=\"https:\/\/fkh.ch\/en\/dienstleistungen\/isolieroelananlysen\/\" target=\"_blank\" rel=\"noopener\">Insulating oil analyses<\/a>)<\/p>\n<p><a href=\"https:\/\/fkh.ch\/wp-content\/uploads\/2019\/11\/Leistungstransformator-Diagnose-V19-01eng.pdf\" rel=\"noopener\">Broschure Power transformer diagnostics<\/a><a href=\"https:\/\/fkh.ch\/wp-content\/uploads\/2019\/11\/Leistungstransformator-Diagnose-V19-01eng.pdf\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-5034\" src=\"https:\/\/fkh.ch\/wp-content\/uploads\/2019\/10\/Leistungstransformator-Diagnose-Bildeng.png\" alt=\"\" width=\"106\" height=\"150\" srcset=\"https:\/\/fkh.ch\/wp-content\/uploads\/2019\/10\/Leistungstransformator-Diagnose-Bildeng.png 794w, https:\/\/fkh.ch\/wp-content\/uploads\/2019\/10\/Leistungstransformator-Diagnose-Bildeng-212x300.png 212w, https:\/\/fkh.ch\/wp-content\/uploads\/2019\/10\/Leistungstransformator-Diagnose-Bildeng-768x1086.png 768w, https:\/\/fkh.ch\/wp-content\/uploads\/2019\/10\/Leistungstransformator-Diagnose-Bildeng-724x1024.png 724w\" sizes=\"auto, (max-width: 106px) 100vw, 106px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/fkh.ch\/wp-content\/uploads\/2019\/11\/Isolieroelanalysen-V19-01eng.pdf\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-5028\" src=\"https:\/\/fkh.ch\/wp-content\/uploads\/2019\/10\/Isolieroelanalysen-Bildeng.png\" alt=\"\" width=\"106\" height=\"150\" srcset=\"https:\/\/fkh.ch\/wp-content\/uploads\/2019\/10\/Isolieroelanalysen-Bildeng.png 794w, https:\/\/fkh.ch\/wp-content\/uploads\/2019\/10\/Isolieroelanalysen-Bildeng-212x300.png 212w, https:\/\/fkh.ch\/wp-content\/uploads\/2019\/10\/Isolieroelanalysen-Bildeng-768x1086.png 768w, https:\/\/fkh.ch\/wp-content\/uploads\/2019\/10\/Isolieroelanalysen-Bildeng-724x1024.png 724w\" sizes=\"auto, (max-width: 106px) 100vw, 106px\" \/><\/a><a href=\"https:\/\/fkh.ch\/wp-content\/uploads\/2019\/11\/Isolieroelanalysen-V19-01eng.pdf\" rel=\"noopener\">Broschure Insulating oil analyses<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>FKH offers on-site diagnostic measurements for both new and service-aged power transformers. For measurements in connection with commissioning, the focus is on inspection of assembly, installation and oil impregnation, and also on characterisation of the transformer for subsequent comparisons (fingerprint in new condition). Diagnostic measurements on service-aged transformers are used to determine the condition of [&hellip;]<\/p>\n","protected":false},"author":194,"featured_media":0,"parent":2254,"menu_order":10,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-2255","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Power transformer diagnostics - FKH<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/fkh.ch\/en\/dienstleistungen\/pruefung-von-hs-betriebsmitteln-vor-ort\/transformatoren-und-andere-apparate\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Power transformer diagnostics - FKH\" \/>\n<meta property=\"og:description\" content=\"FKH offers on-site diagnostic measurements for both new and service-aged power transformers. For measurements in connection with commissioning, the focus is on inspection of assembly, installation and oil impregnation, and also on characterisation of the transformer for subsequent comparisons (fingerprint in new condition). Diagnostic measurements on service-aged transformers are used to determine the condition of [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/fkh.ch\/en\/dienstleistungen\/pruefung-von-hs-betriebsmitteln-vor-ort\/transformatoren-und-andere-apparate\/\" \/>\n<meta property=\"og:site_name\" content=\"FKH\" \/>\n<meta property=\"article:modified_time\" content=\"2019-11-28T12:25:24+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/fkh.ch\/wp-content\/uploads\/2014\/03\/TE-Pr\u00fcfung-Erregung-Dieselgenerator-300x196.jpg\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/fkh.ch\/en\/dienstleistungen\/pruefung-von-hs-betriebsmitteln-vor-ort\/transformatoren-und-andere-apparate\/\",\"url\":\"https:\/\/fkh.ch\/en\/dienstleistungen\/pruefung-von-hs-betriebsmitteln-vor-ort\/transformatoren-und-andere-apparate\/\",\"name\":\"Power transformer diagnostics - FKH\",\"isPartOf\":{\"@id\":\"https:\/\/fkh.ch\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/fkh.ch\/en\/dienstleistungen\/pruefung-von-hs-betriebsmitteln-vor-ort\/transformatoren-und-andere-apparate\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/fkh.ch\/en\/dienstleistungen\/pruefung-von-hs-betriebsmitteln-vor-ort\/transformatoren-und-andere-apparate\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/fkh.ch\/wp-content\/uploads\/2014\/07\/Trafo-Diagramm4-300x204.png\",\"datePublished\":\"2014-03-11T12:02:27+00:00\",\"dateModified\":\"2019-11-28T12:25:24+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/fkh.ch\/en\/dienstleistungen\/pruefung-von-hs-betriebsmitteln-vor-ort\/transformatoren-und-andere-apparate\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/fkh.ch\/en\/dienstleistungen\/pruefung-von-hs-betriebsmitteln-vor-ort\/transformatoren-und-andere-apparate\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/fkh.ch\/en\/dienstleistungen\/pruefung-von-hs-betriebsmitteln-vor-ort\/transformatoren-und-andere-apparate\/#primaryimage\",\"url\":\"https:\/\/fkh.ch\/wp-content\/uploads\/2014\/07\/Trafo-Diagramm4-300x204.png\",\"contentUrl\":\"https:\/\/fkh.ch\/wp-content\/uploads\/2014\/07\/Trafo-Diagramm4-300x204.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/fkh.ch\/en\/dienstleistungen\/pruefung-von-hs-betriebsmitteln-vor-ort\/transformatoren-und-andere-apparate\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/fkh.ch\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Services\",\"item\":\"https:\/\/fkh.ch\/en\/dienstleistungen\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"High Voltage Testing\",\"item\":\"https:\/\/fkh.ch\/en\/dienstleistungen\/pruefung-von-hs-betriebsmitteln-vor-ort\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Power transformer diagnostics\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/fkh.ch\/en\/#website\",\"url\":\"https:\/\/fkh.ch\/en\/\",\"name\":\"FKH\",\"description\":\"High Voltage Testing and Engineering Commission\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/fkh.ch\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Power transformer diagnostics - FKH","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/fkh.ch\/en\/dienstleistungen\/pruefung-von-hs-betriebsmitteln-vor-ort\/transformatoren-und-andere-apparate\/","og_locale":"en_US","og_type":"article","og_title":"Power transformer diagnostics - FKH","og_description":"FKH offers on-site diagnostic measurements for both new and service-aged power transformers. For measurements in connection with commissioning, the focus is on inspection of assembly, installation and oil impregnation, and also on characterisation of the transformer for subsequent comparisons (fingerprint in new condition). Diagnostic measurements on service-aged transformers are used to determine the condition of [&hellip;]","og_url":"https:\/\/fkh.ch\/en\/dienstleistungen\/pruefung-von-hs-betriebsmitteln-vor-ort\/transformatoren-und-andere-apparate\/","og_site_name":"FKH","article_modified_time":"2019-11-28T12:25:24+00:00","og_image":[{"url":"https:\/\/fkh.ch\/wp-content\/uploads\/2014\/03\/TE-Pr\u00fcfung-Erregung-Dieselgenerator-300x196.jpg","type":"","width":"","height":""}],"twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/fkh.ch\/en\/dienstleistungen\/pruefung-von-hs-betriebsmitteln-vor-ort\/transformatoren-und-andere-apparate\/","url":"https:\/\/fkh.ch\/en\/dienstleistungen\/pruefung-von-hs-betriebsmitteln-vor-ort\/transformatoren-und-andere-apparate\/","name":"Power transformer diagnostics - FKH","isPartOf":{"@id":"https:\/\/fkh.ch\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/fkh.ch\/en\/dienstleistungen\/pruefung-von-hs-betriebsmitteln-vor-ort\/transformatoren-und-andere-apparate\/#primaryimage"},"image":{"@id":"https:\/\/fkh.ch\/en\/dienstleistungen\/pruefung-von-hs-betriebsmitteln-vor-ort\/transformatoren-und-andere-apparate\/#primaryimage"},"thumbnailUrl":"https:\/\/fkh.ch\/wp-content\/uploads\/2014\/07\/Trafo-Diagramm4-300x204.png","datePublished":"2014-03-11T12:02:27+00:00","dateModified":"2019-11-28T12:25:24+00:00","breadcrumb":{"@id":"https:\/\/fkh.ch\/en\/dienstleistungen\/pruefung-von-hs-betriebsmitteln-vor-ort\/transformatoren-und-andere-apparate\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/fkh.ch\/en\/dienstleistungen\/pruefung-von-hs-betriebsmitteln-vor-ort\/transformatoren-und-andere-apparate\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/fkh.ch\/en\/dienstleistungen\/pruefung-von-hs-betriebsmitteln-vor-ort\/transformatoren-und-andere-apparate\/#primaryimage","url":"https:\/\/fkh.ch\/wp-content\/uploads\/2014\/07\/Trafo-Diagramm4-300x204.png","contentUrl":"https:\/\/fkh.ch\/wp-content\/uploads\/2014\/07\/Trafo-Diagramm4-300x204.png"},{"@type":"BreadcrumbList","@id":"https:\/\/fkh.ch\/en\/dienstleistungen\/pruefung-von-hs-betriebsmitteln-vor-ort\/transformatoren-und-andere-apparate\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/fkh.ch\/en\/"},{"@type":"ListItem","position":2,"name":"Services","item":"https:\/\/fkh.ch\/en\/dienstleistungen\/"},{"@type":"ListItem","position":3,"name":"High Voltage Testing","item":"https:\/\/fkh.ch\/en\/dienstleistungen\/pruefung-von-hs-betriebsmitteln-vor-ort\/"},{"@type":"ListItem","position":4,"name":"Power transformer diagnostics"}]},{"@type":"WebSite","@id":"https:\/\/fkh.ch\/en\/#website","url":"https:\/\/fkh.ch\/en\/","name":"FKH","description":"High Voltage Testing and Engineering Commission","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/fkh.ch\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/fkh.ch\/en\/wp-json\/wp\/v2\/pages\/2255","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fkh.ch\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/fkh.ch\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/fkh.ch\/en\/wp-json\/wp\/v2\/users\/194"}],"replies":[{"embeddable":true,"href":"https:\/\/fkh.ch\/en\/wp-json\/wp\/v2\/comments?post=2255"}],"version-history":[{"count":20,"href":"https:\/\/fkh.ch\/en\/wp-json\/wp\/v2\/pages\/2255\/revisions"}],"predecessor-version":[{"id":5913,"href":"https:\/\/fkh.ch\/en\/wp-json\/wp\/v2\/pages\/2255\/revisions\/5913"}],"up":[{"embeddable":true,"href":"https:\/\/fkh.ch\/en\/wp-json\/wp\/v2\/pages\/2254"}],"wp:attachment":[{"href":"https:\/\/fkh.ch\/en\/wp-json\/wp\/v2\/media?parent=2255"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}